UNICAN IMMOBILIZER EMULATOR PROGRAM FOR BMW ECUs WITH IMPLEMENTED EWS4 IMMO SYSTEM COMMUNICATING THROUGH CAN BUS AT 500 Kbps.
For proper operation, we need to program the CAN speed on which the ECU operates and the 16-bytes ISN code from the ECU.
In the cell at address 0x01, we enter CAN bus speed value 50 which gives 500 Kbps.
In the cell at address 0x02, we write the value 0x03, which sets the immobiliser library used in the EWS4 ECUs.
In cells starting from address 0x10, enter the 16 bytes of ISN code from the ECU that we intend to unlock.
As the emulator and CAS module cannot communicate with the ECU at the same time, the emulator is intended for engine swaps where the CAS module has been removed from the installation or the authorisation via CANBUS has been deactivated in the CAS configuration.
Four wires should be connected: CAN-H, CAN-L, GND (ground) and +12 V IGN ( terminal „15”) or +12 V after the ECU/ECM relay. Ensure the connection adheres to the vehicle’s repair schematics.
The colors of the corresponding wires are specified in the photo.
The location of the eeprom 24C02 memory is also specified in the photo.
Please remember the CAN terminator – terminator resistor, is in many cases indispensable especially when the ECU works standalone.
The description of the green and red LEDs can be found in the photo, thanks to them we can carry out diagnostics of the emulator connection, they clearly indicate the current status of the CAN bus connection and the status of matching to the ECU.
In order to use this solution, the customer must be qualified as an automotive electronics technician and have the necessary diagnostic tools and wiring diagrams.
In the event of problems and the need for technical support, a CAN bus analyzer will be required in addition to the ECU files, as well as the ability to operate it.